Diferència entre revisions de la pàgina «Siarq's Hybrid 2.2»

De binefa.com
Salta a la navegació Salta a la cerca
Línia 90: Línia 90:
  
 
For instance, byte[21]: 0x4C and byte[22]: 0x00. 0x004C -> 76 (SoC: 76%)
 
For instance, byte[21]: 0x4C and byte[22]: 0x00. 0x004C -> 76 (SoC: 76%)
 +
 +
Byte '''23''': '''VBAT''' (battery's voltage) from Epever's MPPT sensor (Most Significant Byte)
 +
Byte '''24''': '''VBAT''' (battery's voltage) from Epever's MPPT sensor  (Least Significant Byte)
 +
Byte '''25''': '''IBAT''' (battery's current) from Epever's MPPT sensor (Most Significant Byte)
 +
Byte '''26''': '''IBAT''' (battery's current) from Epever's MPPT sensor  (Least Significant Byte)
 +
 +
Byte '''27''': '''vPV''' (photovoltaic panel voltage) from Epever's MPPT sensor (Most Significant Byte)
 +
Byte '''28''': '''vPV''' (photovoltaic panel voltage) from Epever's MPPT sensor  (Least Significant Byte)
 +
Byte '''29''': '''iPV''' (photovoltaic panel current) from Epever's MPPT sensor (Most Significant Byte)
 +
Byte '''30''': '''iPV''' (photovoltaic panel current) from Epever's MPPT sensor  (Least Significant Byte)
 +
Byte '''31''': '''pPV''' (photovoltaic panel power) from Epever's MPPT sensor (Most Significant Byte)
 +
Byte '''32''': '''pPV''' (photovoltaic panel power) from Epever's MPPT sensor  (Least Significant Byte)

Revisió del 20:26, 22 jul 2022

This wiki is written to understand current LoRaWAN protocol being sent by Siarq's Hybrid 2.2 (LoRaWAN version).

LoRaWAN version

alpha-omega-tech-hyb The Things Stack Community Edition Application

Credentials

AppEUI, DevEUI and AppKey

For eui-70b3d57ed0053704 device at alpha-omega-tech-hyb application:

static const u1_t PROGMEM APPEUI[8] = { 0x01, 0x00, 0x00, 0x0C, 0x0B, 0x0A, 0x01, 0x05 }; // Little endian format
static const u1_t PROGMEM DEVEUI[8] = { 0x04, 0x37, 0x05, 0xD0, 0x7E, 0xD5, 0xB3, 0x70 }; // Little endian format
static const u1_t PROGMEM APPKEY[16] = { 0x65, 0x31, 0x77, 0x83, 0x4D, 0xE7, 0x2E, 0x04, 0x54, 0x9A, 0xB3, 0x63, 0xBA, 0x1F, 0x25, 0xC1 }; // Big endian format

MQTT(S)

Broker: eu1.cloud.thethings.network:8883
Username: alpha-omega-tech-hyb@ttn
API key:  NNSXS.S52UVHQC54UAR2CMHGFTLNPARYX2VKWKEOE4QMA.QAWCZOCBTDZMMQLCUL7ORXDAOR7IK75MYO5OZHQ37BX346CZUAXA
uplink topic: v3/alpha-omega-tech-hyb@ttn/devices/eui-70b3d57ed0053704/up


Sensors

Modbus baud rate : 4800 bauds

Noise sensor modbus address: 0x01 (Usually it is not connected if there is a CO2 sensor)

PM sensor modbus address: 0x02

O3 sensor modbus address: 0x03

NO2 sensor modbus address: 0x04

CO2 sensor modbus address: 0x05 (Usually it is not connected if there is a noise sensor)

Byte 0: CO2 sensor or Noise sensor (Most Significant Byte)
Byte 1: CO2 sensor or Noise sensor (Least Significant Byte)

For instance, byte[0]: 0x82 and byte[1]: 0x02 -> 0x0282 = 642 (642ppm if it is CO2 sensor o 64.2dBA if it is a noise sensor)

Byte 2: PM2.5 sensor (Most Significant Byte)
Byte 3: PM2.5 sensor (Least Significant Byte)
Byte 4: PM10 sensor (Most Significant Byte)
Byte 5: PM10 sensor (Least Significant Byte)

For instance, byte[2]: 0x0F, byte[3]: 0x00, byte[4]:0x10 and byte[5]: 0x00 -> 0x000F = 15 (PM2.5: 15ug/m3) and 0x0010 = 16 (PM10: 16ug/m3)

Byte 6: Temperature's O3 sensor (Most Significant Byte)
Byte 7: Temperature's O3 sensor (Least Significant Byte)
Byte 8: Relative humidity's O3 sensor (Most Significant Byte)
Byte 9: Relative humidity's O3 sensor (Least Significant Byte)
Byte 10: Ozone's O3 sensor (Most Significant Byte)
Byte 11: Ozone's O3 sensor (Least Significant Byte)

For instance, byte[6]: 0x13, byte[7]: 0x01, byte[8]:0xC1, byte[9]:0x01, byte[10]:0x04 and byte[11]: 0x00

0x0113 = 275 (Temperature's value should be divided by 10. T: 27.5ºC)

0x01C1 = 448 (Relative humidity's value should be divided by 10. RH: 44.8%)

0x0004 = 4 (Ozone's value should be divided by 1.96. O3: 2.04ug/m3

Byte 12: NO2_WE value from NO2 sensor (Most Significant Byte)
Byte 13: NO2_WE value from NO2 sensor (Least Significant Byte)
Byte 14: NO2_AE value from NO2 sensor (Most Significant Byte)
Byte 15: NO2_AE value from NO2 sensor (Least Significant Byte)
Byte 16: SO2_WE value from NO2 sensor (Most Significant Byte)
Byte 17: SO2_WE value from NO2 sensor (Least Significant Byte)
Byte 18: SO2_AE value from NO2 sensor (Most Significant Byte)
Byte 19: SO2_AE value from NO2 sensor (Least Significant Byte)

NO2 calculus algorithm from NO2_WE and NO2_AE values

Byte 20: Which sensors have been read. (Bit 0: NO2, bit 1: Noise, bit 2: PM, bit 3: O3, bit 4: CO2)

For instance: 0x1D (00011101b -> NO2, PM, O3 and CO2 sensors have been read and noise has not been read)

Epever's MPPT part

Modbus baud rate : 115200 bauds

Epever's MPPT Modbus Commands

SoC MPPT modbus register: 0x311A

BAT MPPT modbus register: 0x331A

PV MPPT modbus register: 0x3100

LED MPPT modbus register: 0x310C

Byte 21: SoC (battery's state of charge) from Epever's MPPT sensor (Most Significant Byte)
Byte 22: SoC (battery's state of charge) from Epever's MPPT sensor  (Least Significant Byte)

For instance, byte[21]: 0x4C and byte[22]: 0x00. 0x004C -> 76 (SoC: 76%)

Byte 23: VBAT (battery's voltage) from Epever's MPPT sensor (Most Significant Byte)
Byte 24: VBAT (battery's voltage) from Epever's MPPT sensor  (Least Significant Byte)
Byte 25: IBAT (battery's current) from Epever's MPPT sensor (Most Significant Byte)
Byte 26: IBAT (battery's current) from Epever's MPPT sensor  (Least Significant Byte)
Byte 27: vPV (photovoltaic panel voltage) from Epever's MPPT sensor (Most Significant Byte)
Byte 28: vPV (photovoltaic panel voltage) from Epever's MPPT sensor  (Least Significant Byte)
Byte 29: iPV (photovoltaic panel current) from Epever's MPPT sensor (Most Significant Byte)
Byte 30: iPV (photovoltaic panel current) from Epever's MPPT sensor  (Least Significant Byte)
Byte 31: pPV (photovoltaic panel power) from Epever's MPPT sensor (Most Significant Byte)
Byte 32: pPV (photovoltaic panel power) from Epever's MPPT sensor  (Least Significant Byte)